Perturbation of localised ultra-clean air delivery systems - INRAE - Institut national de recherche pour l’agriculture, l’alimentation et l’environnement Accéder directement au contenu
Communication Dans Un Congrès Année : 2004

Perturbation of localised ultra-clean air delivery systems

Résumé

The perturbations of localised ultra-clean air delivery systems due to continual access of operators to handle products have been investigated. It was exhibited that the keystone of localised air delivery systems was a turbulent mixing layer modeling the interface between the polluted and the clean air. Furthermore the obstacle penetrating into the clean air flow was represented by a generic shape, the circular cylinder. Hence the problem of perturbation was approached by studying the interaction between the wake of a circular cylinder and a turbulent plane mixing layer. From the analysis of experimental results a local injection of contaminant has been highlighted. Actions to prevent that pollution were deduced and studied on the Progressive Flux, a localised delivery system developped by the Cemagref. The inherent drawback of uni-directional flow systems was demonstrated and explained.
Fichier non déposé

Dates et versions

hal-02583805 , version 1 (14-05-2020)

Identifiants

Citer

Dominique Heitz, C. Braud, P. Georgeault, J. Delville, G. Arroyo. Perturbation of localised ultra-clean air delivery systems. Food Factory of the futur, 2nd International Conference, Laval, 6-8 October 2004, 2004, Laval, France. pp.4. ⟨hal-02583805⟩